Empiria Studio® Software Quick Start
This guide will get you started using Empiria Studio Software to analyze images from an Odyssey Imager or C‑DiGit Blot Scanner.
The LI‑COR® Acquisition Software Quick Start Guide covers getting started with image acquisition.
Create a LI‑COR Account
If you haven't already, create a LI‑COR Account at licor.com/GetEmpiria. You can then purchase Empiria Studio or use your access code.
Download and Install Empiria Studio
Download Empiria Studio at licor.com/EmpiriaStudioDownload (available for macOS or Windows) and install.
Ensure you have the correct permissions to install software on the computer you want to use, and ensure that your computer has the required specifications.
Required
-
A minimum of 8 GB of RAM is required.
-
Windows: Windows 10 (64-bit).
-
macOS: Mojave or Catalina are supported.
Recommended
-
Screen size: Certain components of the Empiria Studio user interface will not display optimally on screen sizes below 1320 x 800 pixels. A screen size of 1920 x 1080 is better for viewing entire plate images for analysis.
-
Dedicated graphics hardware will improve computer performance when working with large, high resolution images. Slide images are likely to be large, high resolution images.
Start Empiria Studio
-
Double-click the Empiria Studio icon on the Desktop.
-
Sign in using your LI‑COR Account credentials.
Create a Data Folder
After signing in, you will be prompted to create a Data Folder A folder on your computer's hard drive where internal Empiria Studio data will be saved. for Empiria Studio to store internal software data. Follow guidelines shown in the software.
Do not put your Data Folder on a network drive or in a folder that automatically syncs with the cloud. Software can be slow when accessing network folders, and data can be lost if multiple people access the data simultaneously.
-
Open the Windows File Explorer or macOS Finder.
-
Create an overall folder (e.g. "Empiria Studio Data Folders") to hold Analysis Data Folders, then create a Data Folder within the overall folder (e.g. "Data Folder 1").
-
In Empiria Studio, select the Data Folder (e.g. "Data Folder 1").
Create a Project
From the Home page, click Project and create a Project Projects contain Experiments. A Project is needed to begin analysis.. A Project is needed to begin analysis.
Import Acquisitions from LI‑COR Acquisition Software
-
Return to the Home page.
-
Open the Image Gallery .
-
In the Image Gallery, click Import LI-COR Zip Files to import Zip Files exported from LI‑COR Acquisition.
-
Select files to import.
Analyze images
-
Return to the Home page.
-
Open Projects and then open the Project you just created.
-
Click Create New Experiment to start analysis.
-
Click the Assay type for the Acquisition you imported to analyze images in that Acquisition.
-
Follow the steps in the Experiment workflow to analyze your assay.
Each column header of the Analysis Table includes a tooltip with a summary about how quantification and other values were calculated. Hover over the header to see the calculation summary.
Export Data and Images
After completing the Experiment workflow, the results will be available on the Review and report page.
-
Click the Export button above a table to export a CSV file or a spreadsheet file.
-
Click the Export button above an image to export a TIFF or PNG image. These image formats should not be used for analysis.
-
Click PDF Report to save a PDF file of the report you are viewing on the Review and report page.
-
Click Experiment File to export the entire Experiment workflow in a format that can be sent to someone else and imported into Empiria Studio on their computer.