Software change log

Version 2.4.51 (current version; released November 25, 2024)

  • Improved SD card formatting and database migration process.
  • Improved LI-7825 laser drive algorithm.

Version 2.4.47 (released August 6, 2024)

  • Added support for the LI-7825 CO2 Isotopes/NH3 Trace Gas Analyzer.
  • Interface refinements.
  • Operational stability improvements for all TGA models.
  • Laser calibration improvements for all TGA models.

Version 2.3.8 (released March 6, 2023)

  • Added High Altitude configuration.

Version 2.3.5 (released December 8, 2022)

  • Improved H2O correction algorithm in LI-7820 instruments.
  • Updated algorithms to improve drift performance in LI-7820 instruments.

Version 2.3.3 (released October 11, 2022)

  • Version 2.3.3 introduces compatibility with a new wireless chipset. No changes to the interface, operation, or performance.

Version 2.1.41 (released February 10, 2022)

New Features

  • Added support for port forwarding.

Bugs Fixed

  • Convert pump tach sync to more accurate math for tighter control.
  • Improve temperature control sensitivity to reduce cavity or thermal enclosure oscillations.
  • Fixed laser power measurement for LI-7820 instruments.
  • Changed dither cavity pressure set point to improve control loop.

Version 2.1.37 (released September 24, 2021)

  • Improved vibration-induced noise performance.
  • Removed A, B, C Pump Adjustment setting; no longer needed due to the improved vibration-induced noise performance.

Version 2.1.35 (released August 18, 2021)

  • Changed graph decimal precision from five places to three places.
  • Changed the way graph tool tips are displayed to ensure correct placement at all screen sizes, including unconventional or uncommon dimensions.
  • Improved detection of user browser/mobile device settings to improve experience across platforms.
  • Fixed bug where History graph would show incorrect end times at certain zoom levels.
  • Fixed bug where certain screen resolutions would render graph tool-tips unreadable.
  • Fixed bug where Android phones could enter a Remark of more than 15 characters.
  • Fixed bug where failing to include end time on a data export would crash the download.
  • Fixed bug where above bug fix would crash download specifically on Safari (all blank end times are now automatically changed to 00:00 of the following day).
  • Fixed bug where History graphs would fail to resize in Safari.
  • Fixed various responsive styling issues in Safari.
  • Fixed bug where Low Flow Config modal was no longer visible on Settings page.
  • Fixed bug where header information (serial number, connection status, etc.) was no longer visible in Spanish language mode.
  • Fixed bug where SD card logging errors in header would not change to reflect selected language mode.
  • Improve second ring-down logic to improve stability when there is a skipped mode.
  • Added functionality to improve handling of fast gas concentration transients.
  • Fix default phase setpoint for TG20.
  • Remove feature to try to keep timestamp at 0 fractional seconds which would break the averager.
  • Remove alternation in zero cal and when initializing start frequency.
  • Expand TG20 self cal laser temperature range.
  • Updated interface so it is compatible with a new browser update.
  • Remove N2O spectra weight from TG10 and TG15 log file.