Metadata dictionary

Metadata describes the setup, instruments, and other parameters. Metadata may be provided for each component of the system.

General metadata

General metadata describes the setup, instruments, and other parameters.

Table 7‑9. All LI-COR devices may include the metadata variables.
Interface
variable
Units Data file
variable
Description
Start Time YYYYMMDD
HHMMSS
TIMESTAMP_START Timestamp at the start of an observation
Total Volume cm3 VOLUME_TOTAL Total volume used in flux calculations
Pre-purge s PREPURGE Pre-purge length
Observation Length s OBSERVATION Observation length
Post Purge s POST_PURGE Post purge length
Horizontal   HORIZONTAL Numerical value of H from chamber's HVR field
Vertical   VERTICAL Numerical value of V from chamber's HVR field

LI-8250 and 8250-01 Extension Manifold metadata

Metadata includes information about the device.

Table 7‑10. Multiplexer and extension manifold metadata definitions. The DEVICE for these variables is LI-8250 or 8250-01 Extension Manifold.
Interface variable Data file variable Description
Serial Number SERIAL_NUMBER Device serial number
Firmware FIRMWARE Device firmware version
Port PORT Port number the observation was made on
Port Label PORT_LABEL User entered description associated with the port
Volume VOLUME Device volume
Latitude LATITUDE Multiplexer latitude in decimal degrees
Longitude LONGITUDE Multiplexer longitude in decimal degrees

8250-02 Calibration Manifold metadata

Metadata includes information about the device.

Table 7‑11. 8250-02 Calibration Manifold metadata definitions.
Interface variable Units Data file variable Description
Serial Number   SERIAL_NUMBER String indicating the serial number
Firmware   FIRMWARE String indicating the device firmware version number
Tube Length cm TUBE_LENGTH Length of tubing connecting the Calibration Manifold to the LI-8250. Contributes to the total system volume.
Volume cm3 VOLUME Volume of internal components.

Long-term Chamber metadata

Metadata includes information about the chamber operation and the soil collar. The 8200-104 and 8200-104C are long-term chambers.

Table 7‑12. LI-COR chamber metadata definitions. The DEVICE for these variables is CHAMBER.
Interface variable Units Data file variable Description
Serial Number   SERIAL_NUMBER Device serial number or chamber type
Firmware   FIRMWARE Device firmware version
Volume cm3 VOLUME Device volume
Tube Length cm TUBE_LENGTH Length of tubing associated with the chamber used to calculate total volume
Collar Height cm COLLAR_HEIGHT Collar height
Area cm2 AREA Soil area
Closing Time s CLOSE_TIME Time it took the chamber to close
Park Position ° PARK Chamber park position
Latitude ° LATITUDE Chamber latitude in decimal degrees
Longitude ° LONGITUDE Chamber longitude in decimal degrees

LI-870 CO2/H2O Analyzer metadata

Metadata includes information about the device.

Table 7‑13. LI-870 metadata definitions. The DEVICE for these variables is LI-870.
Interface variable Units Data file variable Description
Volume cm3 VOLUME Device volume
Tube Length cm TUBE_LENGTH Length of tubing associated with the analyzer used to calculate total volume
Serial Number   SERIAL_NUMBER Device serial number
Firmware   FIRMWARE Device firmware version

LI-78xx Trace Gas Analyzer metadata

Metadata includes information about the device.

Table 7‑14. LI-78xx metadata definitions. The DEVICE for these variables is LI-7810, LI-7815, LI-7820, or LI-7825.
Interface variable Units Data file variable Description
Volume cm3 VOLUME Device volume
Tube Length cm TUBE_LENGTH Length of tubing associated with the analyzer used to calculate total volume
Serial Number   SERIAL_NUMBER Device serial number
Firmware   FIRMWARE Device firmware version