Example Experiment: Characterizing ERK Activation in Response to EGF Treatment in A431 Cells

Background

Accurate quantification of protein expression and/or post-translational modifications is important for advancing both basic and translational research. Given the flexibility, reproducibility, and higher throughput of the In‑Cell Western™ Assay, it offers a convenient alternative to Western blotting and is a powerful platform for meaningful in situ analyses. The In-Cell Western microplate format can be used to analyze:

  • Protein phosphorylation and signaling (1 - 3)
  • Off-target effects of drugs on signaling pathways (4)
  • Timing and kinetics of signaling events (5, 6)
  • Quantification of viral load (7 - 11)
  • Genotoxicity assays (12, 13)
  • Cell proliferation and apoptosis assays (14)
  • Bacterial-induced epithelial signaling (15)
  • Glycoprotein analysis (16, 17)
  • Library screening (18 - 20)
  • Screening of monoclonal antibody clones (21)

Introduction

Due to the multifaceted roles of the EGFR signaling pathway, it is not surprising that the perturbation of this pathway can promote malignant behavior in cancer cells, such as increased cell survival, proliferation, migration, invasion, and the epithelial-mesenchymal transition. Consequently, EGFR has emerged as an attractive target for anti-cancer therapy and understanding how new therapies impact this multi-dimensional pathway is of great importance. EGF stimulates the epidermal growth factor receptor (EGFR), triggering a signal transduction cascade that initiates a variety of biochemical and molecular changes, including the phosphorylation and activation of ERK. Exploring EGFR and its corresponding signaling pathways can provide critical knowledge in understanding both its normal function and role in disease.

Experimental Design

In the following In‑Cell Western™ Assay example, autophosphorylation of EGFR is detected and characterized in A431 cells following stimulation of the EGFR pathway by the epidermal growth factor, EGF. Phosphor-EGFR and total-EGFR levels, used for normalization, were detected using phospho-specific and pan EGFR antibodies. The information obtained from this experimental protocol could be used to identify appropriate experimental conditions to screen for and characterize compounds that modulate this branch of the EGFR signaling pathway.

Required Reagents

LI‑COR Reagents

  • IRDye® 800CW Goat anti-Rabbit Secondary Antibody (LI-COR P/N 926-32211)
  • CellTag™ 700 Stain (LI-COR P/N 926-41090)
  • Intercept® (PBS) Blocking Buffer (licor.com/intercept)

Additional Reagents

  • 1X PBS wash buffer

  • Tissue culture reagents (serum, DMEM, trypsin, 1X PBS)

  • 20% Tween® 20

  • Epidermal Growth Factor (Millipore, P/N 01-107)

  • 37% formaldehyde

  • 10% Triton® X-100

  • Black-sided 96-well or 384-well microplates with clear well bottoms

  • Primary antibodies as described below

    Phosphorylated-EGFR and phosphorylated-ERK are purchased from Cell Signaling Technology and Santa Cruz Biotechnology, respectively. All primary antibodies should be validated for optimal results. Serum starvation of the cells is required to obtain maximal response.

Prepare Cells

  1. Allow A431 cell growth in a T75 flask in DMEM and 10% fetal calf serum (FCS; Gibco®), using standard tissue culture procedures until ~80% confluency is achieved (~1.5 x 107 cells; DMEM, 10% FBS; Gibco).

  2. Remove growth media and wash cells with sterile 1X PBS (room temperature (RT)).

  3. Add trypsin and incubate 3-5 minutes at 37 °C to displace cells.

  4. Neutralize displaced cells with culture media and pellet by centrifugation (500 x g).

  5. Remove supernatant and disrupt the cell pellet manually by hand-tapping the collection tube.

    To maintain cell integrity, do not pipet or vortex during pellet disruption.

  6. Resuspend cells in 20 mL of complete media and count cells using a hemocytometer.

  7. Reconstitute and dilute cells with complete media to a concentration of 200,000 cells/mL.

  8. Manually mix the cell suspension thoroughly.

  9. Under sterile conditions, dispense 200 µL of the cell suspension per well in a 96-well plate (40,000 cells plated per well).

  10. Incubate cells at 37 °C and monitor cell density until cells are consistently confluent in each well. This should take approximately three days.

Treat Cells

  1. Warm serum-free media (DMEM, Gibco) to 37 °C.
  2. Remove complete media from the multiwell plate by aspiration.
  3. Replace media with 200 µL of pre-warmed, serum-free media per well, and incubate 4 to 16 hours.
  4. In a separate 96-well Multiwell plate, dispense 100 µL of DMEM per well.
  5. Leave the first and second wells without EGF (resting cells controls). In the remaining wells, add aliquots of a solution of EGF to make serial dilutions ranging 0.2 to 100 ng/mL in the microplate. The experimental layout should look like that shown in Figure 140.
  6. Carefully remove starvation media from plate wells by aspiration.
  7. Transfer EGF dilutions from the dilution plate into the cell-containing plate.
  8. Incubate at 37 °C for 7.5 minutes.

Fix and Permeabilize Cells

Fix Cells

  1. Prepare fresh Fixing Solution as follows:

    1X PBS45 mL
    37% Formaldehyde5 mL
    3.7% Formaldehyde50 mL
  2. When incubation period is complete, carefully remove activation media manually or by aspiration to avoid detaching the cells.

  3. Using a multi-channel pipettor, add 150 µL of fresh Fixing Solution (RT). Add the solution by pipetting down the sides of the wells carefully to avoid detaching the cells from the well bottom.

  4. Allow incubation on bench top for 20 minutes at RT with no shaking.

Permeabilize Cells

  1. Prepare Triton® Washing Solution as follows:

    1X PBS 495 mL
    10% Triton X-1005 mL
    1X PBS + 0.1% Triton X-100500 mL
  2. Remove Fixing Solution to an appropriate waste container (contains formaldehyde).

  3. Using a multi-channel pipettor, add 200 µL Triton Washing Solution (RT). Add the solution down the sides of the wells carefully to avoid detaching the cells.

  4. Allow plate to shake on a rotator for 5 minutes at RT.

  5. Repeat washing steps 4 more times, removing wash manually each time.

    Do not allow cells to become dry during washing. Immediately add the next wash after manual disposal.

Block Cells

  1. Using a multi-channel pipettor, add 150 µL of Intercept® Blocking Buffer to each well. Add the solution by pipetting down the sides of the wells carefully to avoid detaching the cells.
  2. Allow blocking for 1.5 hours at RT with moderate shaking on a plate shaker.

Primary Antibodies

Dilute Primary Antibodies

  1. Dilute the antibodies in Intercept Blocking Buffer to the concentrations specified below.

  2. Primary antibodies can be added in a variety of combinations. Generally, one antibody will be directed against the phosphorylated form of the target protein and the second antibody will be directed against the target protein, regardless of phosphorylation status. The following are suggested combinations of primary antibodies, depending on the target to be detected:

    • Phospho-EGFR Tyr1045 (Rabbit; 1:100 dilution in the combined solution; Cell Signaling Technology, P/N 2237)

      Total EGFR (Mouse; 1:500 dilution; Invitrogen, P/N AHR5062)

    • Phospho-ERK (Mouse; 1:100 dilution in the combined solution; Santa Cruz Biotechnology, P/N SC-7383)

      Total ERK1 (Rabbit; 1:200 dilution; Santa Cruz Biotechnology, P/N SC-94)

  3. Add 50 µL of Intercept Blocking Buffer to one set of wells. These wells will serve as a control for any potential background due to the dye-labeled secondary antibody. See Figure 140 for an example of the desired plate layout.

  4. Mix the primary antibody solution thoroughly before adding to wells.

Incubate with Primary Antibodies

  1. Remove the blocking buffer from the blocking step and add 50 µL of the desired primary antibody combination to cover the bottom of each well.
  2. Incubate with primary antibody for 2 hours with gentle shaking at RT.

Wash

  1. Prepare Tween® Washing Solution as follows:

    1X PBS995 mL
    20% Tween 205 mL
    1X PBS + 0.1% Tween 201000 mL
  2. Remove primary antibody solution.

  3. Using a multi-channel pipettor, add 200 µL Tween Washing Solution (RT). Add solution down the sides of the wells carefully to avoid detaching the cells from the well bottom.

  4. Allow wash to shake on plate shaker for 5 minutes at RT.

  5. Repeat washing steps 4 more times.

Secondary Antibodies

Dilute Secondary Antibodies

  1. Dilute the fluorescently-labeled secondary antibodies in Intercept® Blocking Buffer as specified below. To lower background, add Tween 20 to the diluted antibody to a final concentration of 0.2%. Recommended dilution range is 1:200 – 1:1,200.

    Goat anti-Rabbit IRDye® 680RD (1:800 dilution in the combined solution)

    Goat anti-Mouse IRDye 800CW (1:800 dilution in the combined solution)

    Minimize exposure of the antibody vials to light.

  2. Mix the antibody solutions and add 50 µL of the secondary antibody solution to each well.

Incubate with Secondary Antibodies

  1. Incubate for 60 minutes with gentle shaking at RT. Protect plate from light during incubation.

Wash

  1. Remove secondary antibody solution.
  2. Using a multi-channel pipettor, add 200 µL of Tween Washing Solution at RT (Wash). Add solution down the sides of the wells carefully to avoid detaching the cells from the well bottom.
  3. Allow wash to incubate on a plate shaker for 5 minutes at RT.
  4. Repeat washing steps 4 more times. Protect plate from light during washing.

Image

  1. After final wash, remove wash solution completely from wells. Turn the plate upside down and tap or blot gently on paper towels to remove traces of wash buffer. For best results, scan plate immediately; plates may also be stored at 4 °C for several weeks (sealed and protected from light).
  2. Before plate scanning, clean the bottom plate surface and the Odyssey® Imager scanning bed (if applicable) with moist, lint-free tissue to avoid any obstructions during scanning.
  3. Scan plate with detection in both 700 and 800 nm channels.

Suggested Scan Settings

All settings may require adjustment for optimal data quality. Higher resolutions or scan qualities can be used, but the scan time will increase.

InstrumentResolutionScan QualityIntensity Setting (700 nm)Intensity Setting (800 nm)
Odyssey Classic169 µMlowest55
Odyssey DLx169 µMlowestAuto ModeAuto Mode

Experimental Results

Quantitative and simultaneous measurements of EGFR and phosphorylation of EGFR in response to EGF stimulation

Figure 140. Dose response of A431 cells to Epidermal growth factor (EGF) as measured by specific antibody detecting phosphorylated EGF receptor (Tyr1045). The image represents a 96-well, two-color In‑Cell Western™ Assay. Detection of EGFR autophosphorylation, showing composite image (top), total EGFR (middle), and increasing amounts of EGFR autophosphorylation (bottom). Background wells were incubated with secondary antibody but no primary antibody. The graph represents normalized quantification of the duplicate fluorescence results.

Quantitative and simultaneous measurements of total ERK and phosphorylation of ERK in response to EGF stimulation

Figure 141. Dose response of A431 cells to Epidermal growth factor (EGF) as measured by specific antibody detecting phosphorylated ERK receptor (Tyr204). The image represents a 96-well, two-color In‑Cell Western™ Assay. (Top) Composite image showing the fluorescence of the microplate in both the 700 nm and 800 nm detection channels. Duplicate rows are shown. (Middle) Detection of total ERK protein regardless of phosphorylation status (pan protein). (Bottom) Detection of increasing amounts of phosphor-ERK as a function of increasing amounts of EGF stimulation. Background wells were incubated with secondary antibody but no primary antibody. The graph represents normalized quantification of the duplicate fluorescence results.

References

1. Chen, H., Kovar, J., Sissons, S., Cox, K., Matter, W., Chadwell, F., Luan, P., Vlahos, C. J., Schutz-Geschwender, A., and Olive, D. M. (2005) A cell-based immunocytochemical assay for monitoring kinase signaling pathways and drug efficacy. Analytical biochemistry 338, 136-142

2. Aguilar, H. N., Zielnik, B., Tracey, C. N., and Mitchell, B. F. (2010) Quantification of rapid Myosin regulatory light chain phosphorylation using high-throughput in-cell Western assays: comparison to Western immunoblots. PLoS One 5, e9965

3. Wong, S. K. (2004) A 384-well cell-based phospho-ERK assay for dopamine D2 and D3 receptors. Analytical biochemistry 333, 265-272

4. Kumar, N., Afeyan, R., Kim, H. D., and Lauffenburger, D. A. (2008) Multipathway model enables prediction of kinase inhibitor cross-talk effects on migration of Her2-overexpressing mammary epithelial cells. Mol Pharmacol 73, 1668-1678

5. Hannoush, R. N. (2008) Kinetics of Wnt-driven beta-catenin stabilization revealed by quantitative and temporal imaging. PLoS One 3, e3498

6. Chen, W. W., Schoeberl, B., Jasper, P. J., Niepel, M., Nielsen, U. B., Lauffenburger, D. A., and Sorger, P. K. (2009) Input-output behavior of ErbB signaling pathways as revealed by a mass action model trained against dynamic data. Mol Syst Biol 5, 239

7. Counihan, N. A., Daniel, L. M., Chojnacki, J., and Anderson, D. A. (2006) Infrared fluorescent immunofocus assay (IR-FIFA) for the quantitation of non-cytopathic and minimally cytopathic viruses. J Virol Methods 133, 62-69

8. Lin, Y. C., Li, J., Irwin, C. R., Jenkins, H., DeLange, L., and Evans, D. H. (2008) Vaccinia virus DNA ligase recruits cellular topoisomerase II to sites of viral replication and assembly. J Virol 82, 5922-5932

9. Weldon, S. K., Mischnick, S. L., Urlacher, T. M., and Ambroz, K. L. (2010) Quantitation of virus using laser-based scanning of near-infrared fluorophores replaces manual plate reading in a virus titration assay. J Virol Methods 168, 57-62

10. Lopez, T., Silva-Ayala, D., Lopez, S., and Arias, C. F. (2012) Methods suitable for high-throughput screening of siRNAs and other chemical compounds with the potential to inhibit rotavirus replication. J Virol Methods 179, 242-249

11. Wan, Y., Zhou, Z., Yang, Y., Wang, J., and Hung, T. (2010) Application of an In-Cell Western assay for measurement of influenza A virus replication. J Virol Methods 169, 359-364

12. Jamin, E. L., Riu, A., Douki, T., Debrauwer, L., Cravedi, J. P., Zalko, D., and Audebert, M. (2013) Combined genotoxic effects of a polycyclic aromatic hydrocarbon (B(a)P) and an heterocyclic amine (PhIP) in relation to colorectal carcinogenesis. PLoS One 8, e58591

13. Khoury, L., Zalko, D., and Audebert, M. (2013) Validation of high-throughput genotoxicity assay screening using gammaH2AX in-cell western assay on HepG2 cells. Environ Mol Mutagen 54, 737-746

14. Godin-Heymann, N., Ulkus, L., Brannigan, B. W., McDermott, U., Lamb, J., Maheswaran, S., Settleman, J., and Haber, D. A. (2008) The T790M "gatekeeper" mutation in EGFR mediates resistance to low concentrations of an irreversible EGFR inhibitor. Mol Cancer Ther 7, 874-879

15. Du, Y., Danjo, K., Robinson, P. A., and Crabtree, J. E. (2007) In-Cell Western analysis of Helicobacter pylori-induced phosphorylation of extracellular-signal related kinase via the transactivation of the epidermal growth factor receptor. Microbes Infect 9, 838-846

16. McInerney, M. P., Pan, Y., Short, J. L., and Nicolazzo, J. A. (2017) Development and Validation of an In-Cell Western for Quantifying P-Glycoprotein Expression in Human Brain Microvascular Endothelial (hCMEC/D3) Cells. J Pharm Sci 106, 2614-2624

17. Urlacher T, Xing K, Cheung L et al (2013) Glycoprotein applications using near-infrared detection. Poster presentation, Experimental Biology

18. Guo, K., Shelat, A. A., Guy, R. K., and Kastan, M. B. (2014) Development of a cell-based, high-throughput screening assay for ATM kinase inhibitors. J Biomol Screen 19, 538-546

19. Hoffman, G. R., Moerke, N. J., Hsia, M., Shamu, C. E., and Blenis, J. (2010) A high-throughput, cell-based screening method for siRNA and small molecule inhibitors of mTORC1 signaling using the In Cell Western technique. Assay Drug Dev Technol 8, 186-199

20. Schnaiter, S., Furst, B., Neu, J., Waczek, F., Orfi, L., Keri, G., Huber, L. A., and Wunderlich, W. (2014) Screening for MAPK modulators using an in-cell western assay. Methods Mol Biol 1120, 121-129

21. Daftarian, M. P., Vosoughi, A., and Lemmon, V. (2014) Gene-based vaccination and screening methods to develop monoclonal antibodies. Methods Mol Biol 1121, 337-346

22. Newton, A. C. (2018) Protein kinase C: perfectly balanced. Crit Rev Biochem Mol Biol 53, 208-230

23. Garg, R., Benedetti, L. G., Abera, M. B., Wang, H., Abba, M., and Kazanietz, M. G. (2014) Protein kinase C and cancer: what we know and what we do not. Oncogene 33, 5225-5237

24. Castagna, M., Takai, Y., Kaibuchi, K., Sano, K., Kikkawa, U., and Nishizuka, Y. (1982) Direct activation of calcium-activated, phospholipid-dependent protein kinase by tumor-promoting phorbol esters. J Biol Chem 257, 7847-7851

25. Ono, Y., Fujii, T., Igarashi, K., Kuno, T., Tanaka, C., Kikkawa, U., and Nishizuka, Y. (1989) Phorbol ester binding to protein kinase C requires a cysteine-rich zinc-finger-like sequence. Proc Natl Acad Sci U S A 86, 4868-4871

26. Ueda, Y., Hirai, S., Osada, S., Suzuki, A., Mizuno, K., and Ohno, S. (1996) Protein kinase C activates the MEK-ERK pathway in a manner independent of Ras and dependent on Raf. J Biol Chem 271, 23512-23519