Odyssey XF Imager Specifications
Specifications
Operating Conditions: For Indoor use only; operating temperature 22 °C, non-condensing; maximum operating temperature may be reduced at elevations above 2000 m.
and dew point <Environmental Conditions: Pollution Degree 2.
Dynamic Range: 22 bit (>6 logs)
Depth of Field for Best Sample Focus: 6 mm
Patented FieldBriteTM Technology: CV <3%
600 Channel Light Source: Light source at 520 nm
700 Channel Laser Source: Solid-state Laser Diode at 685 nm
800 Channel Laser Source: Solid-state Laser Diode at 785 nm
Laser Lifetime: 20,000 hours
Detector Type: Low-noise CCD. Thermoelectrically cooled.
Acquisition Times:
600, 700 and 800 nm channels: 30 s, 2 min, 10 min plus advanced variable time feature.
Chemiluminescence channel: 30 s, 2 min, 10 min, 60 min plus advanced variable time feature.
Focusing: None needed.
Sensitivity: Similar to Odyssey® DLx Imaging System
Wavelength Maxima for Excitation/Emission Bands:
Channel | Excitation | Emission |
600 nm | 520 nm | 600 nm |
700 nm | 685 nm | 730 nm |
800 nm | 785 nm | 830 nm |
Chemiluminescence | none | Visible |
Dyes: Optimized for LI‑COR® IRDye® 680RD and IRDye® 800CW reagents, and chemiluminescent substrates.
Image Display Options: Pseudocolor, positive and negative grayscale, single color (red, green or blue), or two colors with overlapping fluorescence displayed in a third color.
Capacity: One imaging tray containing one blot or gel.
Field of View: 10 cm D × 12 cm W (3.9” D × 4.7” W) at the surface of the imaging bed.
Power Requirements: Universal input range is between 100-127 VAC and 200-240 VAC (voltage fluctuations not to exceed 10% of the nominal voltage); 50/60 Hz; at 120V, 4 Amp maximum; at 120V, 0.3 Amp typical when idle. Overvoltage Category II.
Computer Connection Cable: Cat. 5e RJ45, 10BASE-T/100BASE-TX/1000BASE-T. Use only the supplied cable.
Size: 67.3 H × 41.4 W × 47 D cm (26.5 H × 16.3 W × 18.5 D inches). Depth with imaging drawer open is 59.7 cm (23.5”).
Weight: 27 kg (60 lbs).
The Odyssey XF Imager is certified as a Class 1 laser product. Hazardous laser radiation is not emitted outside the instrument. Radiation emitted inside the Odyssey XF Imager is confined within protective housings and external covers. A series of safety interlocks ensures that laser beams cannot escape during any phase of user operation.
Detection Channel Summary
Channel | Excitation / Illumination | Emission Filter | Assay Category / Imaging Mode |
---|---|---|---|
800 | 785 nm | 816 - 846 nm | Membrane, Gel |
700 | 685 nm | 716 - 746 nm | Membrane, Gel |
Chemi | NA | NA | Membrane |
600 | 520 nm | 573 - 637 nm | Membrane, Gel |